| Home | Mailing Lists | Bookstore | Weather | Tide Predictions | Bowditch |

Re: T&T: Alarm Mute Control

From: Arild Jensen (no email)
Date: Wed Apr 23 2008 - 00:17:18 EDT

  • Next message: GARY RITZMAN: "T&T: A very public thank you to this list"

    > -----Original Message-----
    > From: Frank Burrows

    > I would like to keep the existing bells but provide some way to mute them
    > but have them automatically reset after the alarm event.
    >
    > Does anyone have a circuit diagram for a resettable mute button?

    REPLY
    Use a Form C double pole relay. The one circuit is for the Bell. Wire the
    normally closed circuit in series with the bell.

    the other pole ( circuit) is used to latch the relay in th eenergizzed
    position.
    A momentary push button momentarily enrgizes the coil. When the NO contact
    closes it feed power back to th ecoil thus latchign it open. Meanwhiel the
    NC contacts breaks the bel circuit when relay is enrgized.

    Remove power and relay drops out. That restores bell circuit and drop out
    the coil holding circuit.
    Arild
    _______________________________________________
    http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering

    To unsubscribe or modify your subscription options (get password, change email address, etc) go to: http://lists.samurai.com/mailman/options/trawlers-and-trawlering