This will be my short answers based on 7 year of experience after doing
exactly the same thing. When I first did the switch, I used 2 GC's for a
start bank for both of my SP135 Lehmans, and 6 GC's for a house bank. I've
since just left all 8 in parallel because no matter how bad I drain them all
down, I've never had them fail to start the engines.
> 1.? Is this even a good idea?? My major concern is will four 6v batteries
> provide cranking power for my FL135?
Yes, it's a great idea. 2 GC's ALWAYS started my Lehmans just fine.
>
> 2.? Has anybody done this (I know the answer to that!)? When you did this,
> which batteries did you use and has it provided the power that you
> expected?
I first used cheap Exides, and got everything I expected for 6 1/2 years.
Switched recently to another brand, and am working through some problems.
>
> 3.? Do you feel any cost differences are significant and if so, worth the
> difference.
Yes, and yes. Two GC's are cheaper than a 4D, and give more power.