    > i currently have 4 x 2000 + 1 3600 on my 53 footer... planning on adding
    > at
    > least one more 3600.
    >
    > Pascal
    > miami, fl
    > 70 hatteras 53MY
    > live helm cam @ www.sandbarhopper.com

    Pascal has a good layout- multiple pumps with remote alarms on them.

    I suggest that any time you are designing or rebuilding systems on a boat
    you go to David Pascoe's website: http://www.yachtsurvey.com/ You can find
    articles from why windows leak and what to do about them to electrolysis.
    Here's his article on bilge pumps:
    http://www.yachtsurvey.com/bilge_pumps.htm

    A few weeks ago I detailed Cigano's bilge pump system which was laid out
    using Pascoe's logic. Three Rule 3700's with float switches and alarms in
    the FB, mounted 1 1/2" above the bilge, and one Rule 1100 as a maintenance
    pump mounted in the bilge low point. All are on separate power sources.

    Another point that Pascal mentioned but which I don't think he emphasized
    enough is head height. That Rule 3700 quickly turns into something less for
    every inch you push the water uphill.

    Another point is illustrated by a fellow listee's boat sinking in his slip
    recently. He had no siphon breaks and the thru-hulls were not very far above
    the WL. Boat was heeled over enough to submerge them. When the boat took on
    some water during a rain storm, the pumps dutifully pumped the bilge dry but
    when the float switch shut them off, water immediately began to siphon back
    in. He still would have been OK but there was a power failure and the
    batteries finally went flat and the boat went down.

    Moral: One little workhorse pump with float switch mounted low, lotsa big
    pumps with float switches and remote alarms mounted higher, hoses with
    siphon breaks and through hulls installed well above the WL. Oh, try to have
    as many different power sources as possible.

    As for 120vac, big box, basement pumps, there's no savings over a 12 vdc
    bilge pump. I shopped this very idea at Lowe's and to get north of 2500 gph,
    you quickly get over $150. Check out the Rule 3700 for $129.99 here:
    http://www.boatbandit.com/rule-3700-pump-4143.aspx

    Regards,

    Larry and Teri
    M/V Cigano, 47' Prairie Sundeck Cruiser
    Lying: Covington, LA
    N 30 26.7
    W 90 07.1
    _______________________________________________
    http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering

    To unsubscribe or modify your subscription options (get password, change email address, etc) go to: http://lists.samurai.com/mailman/options/trawlers-and-trawlering

    Trawlers & Trawlering and T&T are trademarks of Water World
    Productions. Unauthorized use is prohibited.


  • Next message: Henry Quigley: "Re: T&T: Fw: Caution on R.O. systems"



    | Home | Mailing Lists | Bookstore | Weather | Tide Predictions | Bowditch | Trawlerworld |