From: Steve Sipe (no email)
Date: Mon Apr 30 2007 - 17:54:38 EDT
Ken Williams wrote:
> Greetings,
> Marine Air Systems 16,000 btu air conditioner. (about 10 years old). Don't use
> it too much, but when I turned it on today, it sounds fine and seems to be
> running fine. But the compressor case is 225 degrees on the Pyrometer. To hot
> to touch! Seems excessive to me. Well vented and clean. What do you think?
> Thanks!
>
Sounds like it might be low on charge. Check your delta-T (difference
between evaporator entering/leaving air in cooling), it should be 20F or
close. Check the suction line (largest one) at the compressor, it should
be sweating or cold to touch, in the 35-40F range. All values are
relative, not absolute. Your compressor derives motor cooling from the
refrigerant flowing through it, if the refrigerant charge has absorbed
as much heat as it can (superheat) by the time it gets to the
compressor, the compressor has no means to dissipate its heat, so it
goes out through the case. Very hard on it. There has to be enough
refrigerant in the system to absorb the amount of heat the evap coil can
transfer with enough capacity to absorb the heat from the compressor.
The condenser circuit then gives up the accumulated head as the
refrigerant condenses back into a liquid. The compressor's job is to
take the low pressure superheated gas & compress it into high pressure,
the condenser can then remove the heat as it condenses it.
End of lesson.
Short version: Dimes to donuts it's undercharged.
Steve Sipe
_______________________________________________
http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering
To unsubscribe send email to
with the word
UNSUBSCRIBE and nothing else in the subject or body of the message.
Trawlers & Trawlering and T&T are trademarks of Water World
Productions. Unauthorized use is prohibited.
|