Re: T&T: (Potentially) Catastrophic Electrical Shut-down

From: Richard (no email)
Date: Thu Apr 12 2007 - 16:11:15 EDT

  • Next message: Gil Johnson: "T&T: To regisiter w/state or not?"

     The best
    > explanation I've found so far is that the batteries were so close to the
    > end
    > of their lives that equalizing simply killed them off. The fumes were
    > evidence of the degradation of the plates. The inverter sensed the absence
    > of charge in the battery banks, and went 'balls to the wall' as long as it
    > could to restore capacity.

    Amazing that you did not get the hint from the 'acrid air'. The instructions
    for equalize in all manuals I have seen say 'do not leave the batteries
    unattended during equalize', and most require that batteries be at normal
    fluid levels before equalize. The fumes had little or nothing to do with
    degradation of the plates, everthing to do with too little care and
    attention to the process. Once batteries go into thermal runaway, which is a
    small possiblity here, the only thing to do is complete disconnect, that is
    no charge, no load. This is also not a time to attempt adding water.

    It is also possible (but unlikely) that the odor came from a source other
    than the batteries.

    Many inverters have a time component in the charge cycle that will limit the
    period of time bulk charge was on. (also true for equalize). Check to see
    that the standard times have not been tampered with. The situation you
    describe was much more common with ferroresonant chargers that typically did
    not have time control on the charge cycle.

    Aside from the electric fuel pump possibility, if the engine has a very
    large alternator and is a moderate size engine, it is possible the engine at
    idle was stalled by the alternator load if the alternator was fully loaded
    serving all the electric demands. I would go over every connection in your
    high amp circuitry and check for 'clean and tight' after an event like this.
    Also check on wire sizes and breaker functioning. Look for signs of burned
    wire ends especially under connectors or other areas where wires are
    'packed'.

    Consider a breaker on your charge line from the alternator sized to protect
    the wire.
    Richard
    _______________________________________________
    http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering

    To unsubscribe send email to
     with the word
    UNSUBSCRIBE and nothing else in the subject or body of the message.

    Trawlers & Trawlering and T&T are trademarks of Water World
    Productions. Unauthorized use is prohibited.


  • Next message: Gil Johnson: "T&T: To regisiter w/state or not?"



    | Home | Mailing Lists | Bookstore | Weather | Tide Predictions | Bowditch | Trawlerworld |