| Home | Mailing Lists | Bookstore | Weather | Tide Predictions | Bowditch |

Re: T&T: 230v/50Hz

From: Al Thomason (no email)
Date: Mon Mar 05 2007 - 18:44:06 EST

  • Next message: (no name): "T&T: Fuel gauge"

    Right, In my case, the 2nd inverter is installed in such a way that this will
    not happen. There is a dedicated line in to the 2nd inverter when it is used
    as a '50hz battery charger'. The normal ship shore power hence does not get
    energized and hence the primary inverter will not switch into pass through
    mode, only invert mode.

    -al-

    ----- Original Message -----
      From: Scott H.E. Welch
      To:
      Cc: Al Thomason
      Sent: Monday, March 05, 2007 1:38 PM
      Subject: Re: T&T: 230v/50Hz
      You need to be very careful about this. Many inverter/chargers are also
    automatic 110V switches as well. When they see good AC power, they switch the
    load over to the incoming power instead of running the inverter.
    _______________________________________________