From: Arild Jensen (no email)
Date: Wed Nov 30 2005 - 21:26:33 EST
-----Original Message-----
From: John Hinshaw
My house bank could be a bit more complicated. Presently I
have 2 "sets" of 6 volt batteries - ie 4 batteries. That in itself is
just like the starting banks. But, if I add another "set" or 2 6 volt
batteries am I creating a charging problem? Can I find a combiner to
handle 3 sets of batteries? Or should I stick with the 2 "sets"? By the
way, the alternator that charges those batteries is a much larger
alternator.
REPLY
Pathmaker from Xantrex does offer a three bank combiner . . . But why
do it that way?
The house bank should consist of all the batteries in one whole block
not split apart.
Arild