I am not sure that this is your problem, but it may be. Prosine has had a
warning out for a few years now that after some large number of cycles, the
contacts that connect / disconnect the shore power when in the inverting mode will
weld together. For some time, there was the warning that there was a software
failure that would not warn you and disable the system. Apparently your
software worked, but the contacts may be frozen or welded together. The danger here
is that if the contacts do not open, then your shore power terminal on the
boat is hot with 120v AC during inverting.