    I brought mine home where I have an air compressor. Using adaptors I
    pressurized one side to about 20 PSI and stuck it in a bucket of water. No
    bubbles.

    Later, using a filler cap adaptor I pressurized the fresh water system to
    about 15 PSI which revealed a tiny hose leak that had previously escaped
    detection. The normal cap pressure on my Ford Lehman is only about 7 PSI.

    Jerry & Barb O'Neill