From: Lee Licata (no email)
Date: Thu Sep 01 2005 - 03:30:40 EDT
Maurice,
If the boat can handle the weight, then the auto-ranging transformer
has to go downstream of the isolation transformer?
Lee
Ankara Turkey
From: <>
Date: August 31, 2005 23:40:12 EEST
To: <>
Subject: Re: T&T: Isolation Transformer
Reply-To:
It also means that there is no DC path from anything AC on the boat
to shore, as AC will not go through a transformer. NB, THIS DOES NOT
INCLUDE AN AUTOTRANSFORMER which does not offer any isolation
benefits
Maurice
_______________________________________________
http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering
To unsubscribe send email to
with the word
UNSUBSCRIBE and nothing else in the subject or body of the message.
Trawlers & Trawlering and T&T are trademarks of Water World
Productions. Unauthorized use is prohibited.
|