From: Philip J. Rosch (no email)
Date: Thu Sep 02 2004 - 21:29:28 EDT
If you have room in the hose from the raw water pump to the HEX, put in a
small plastic strainer. That way the broken vanes end up in the strainer
rather than the HEX which can be a nightmare...
Regards....
Phil Rosch
Old Harbor Consulting
M/V Curmudgeon MT-44TC
Currently moored in New Harbor, Block Island, RI
-----Original Message-----
From:
[mailto:] On Behalf Of Gary
Brobst
Sent: Wednesday, September 01, 2004 9:23 AM
To: trawlers-and-trawlering@;
Subject: Re: T&T: Onan MDKD impellers and filters
Ron,
Odds are very good that the impeller blades are in the heat exchanger. I
consider it SOP to dismantle the raw water cooling system if any impeller
blades are missing and have generally found all the pieces. That is my
penalty for waiting too long to change impellers. As for the cover plate on
my Jabsco pumps, I replaced the slotted head screws with SS socket head cap
screws (found with google search) and now use an allen wrench.
Ron wrote:
>Just finished changing the impeller - only 3 blades were left - god
>knows where the others are ..................Those by the way are 8mm bolts
and I found a socket
>worked OK instead of a right angled screw driver.
Gary Brobst
m/v Waypoint
49' Defever RPH
Currently in Fort Walton Beach FL
_______________________________________________
http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering
To Unsubscribe send email to
Include the word Unsubscribe (and nothing else) in the subject or body of
the message.
_______________________________________________
http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering
To Unsubscribe send email to
Include the word Unsubscribe (and nothing else) in the subject or body of the message.
|