From: Paul Goyette (no email)
Date: Mon Aug 30 2004 - 02:38:46 EDT
Well, if it's talking about wire with a 50 _square_ mm cross section,
(that would be "50" followed by "mm" followed by a raised "2"), the
wire has a diameter of some 8mm, or roughly 1/3 of an inch.
On Mon, 30 Aug 2004 wrote:
> Good grief! Two inches?!! I went back to the manual to confirm, and it does say "50 mm." Must be a misprint, but is in progression with other sizes for larger and smaller motors. Go figure. Good for a late night chuckle, anyway. I am thinking 1.0 should do it, but would be very interested in Arild's thoughts. There is a "2" just above and to the right of the mm, which I took to be a footnote, which I can't find...but if that were a "square" sign, we would be talking 250, wouldn't we? Hmmmm.
>
> As to the breaker, I currently have a 1000 watt Lofrans winch (the new one is 1200 watt). I have been using 125 amp Blue Seas breaker. It was here when I got the boat and is working fine...so far. The old windlass is doing well, but is 20 years old, will be rehabbed and used for a rainy day backup.
> _______________________________________________
> http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering
>
> To Unsubscribe send email to
> Include the word Unsubscribe (and nothing else) in the subject or body of the message.
>
>
----------------------------------------------------------------------
| Paul Goyette | PGP DSS Key fingerprint: | E-mail addresses: |
| Network Engineer | FA29 0E3B 35AF E8AE 6651 | |
| & World Cruiser | 0786 F758 55DE 53BA 7731 | |
----------------------------------------------------------------------
_______________________________________________
http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering
To Unsubscribe send email to
Include the word Unsubscribe (and nothing else) in the subject or body of the message.
|