    > -----Original Message-----
    > The concerns about the batteries causing he whole boat to become unstable is
    > unfounded unless the dinette is located 10 or 15 feet above the water line.
    > Not likely except on a megayacht.
    > By my calculations 2000 A-H would equal the weight of about four or five
    > normal adults males.

    Arild,

    The 8D batteries I'm familiar with come in a 220 AmpHrs and 165 pounds each.
    That comes down to nine 8D batteries to get to 1980 Amp Hrs, for a total weight
    (without boxes, cable and connectors) of 1,485 pounds (1,650 pounds if you want
    to get over 2000 AmpHrs). That is more like eight 180 pound adult males.

    That is indeed a significant amount of additional weight to be added that high
    (in addition to the normal passenger and gear load), and will definitely raise
    the CG of the vessel a significant degree.

    If I was going to add that type of permanently installed weight in a vessel of
    that size, I would want a naval architect to review the numbers and make sure
    the boat's stability is not being compromised.

    Kevin
    _______________________________________________
    http://lists.samurai.com/mailman/listinfo/trawlers-and-trawlering

    To Unsubscribe send email to
    Include the word Unsubscribe (and nothing else) in the subject or body of the message.


  • Next message: Bob Peterson: "T&T: RE: RE: battery box ventillation"



    | Home | Mailing Lists | Bookstore | Weather | Tide Predictions | Bowditch | Trawlerworld |