Re: TWL: Single 50A vs Two 30A

From: (no name) (no email)
Date: Fri Jan 02 2004 - 10:39:41 EST

  • Next message: J Kaster: "TWL: Re: Tenn-Tom"

    In a message dated 1/2/04 10:15:22 AM Eastern Standard Time,
     writes:

    > We also carry a plethora of adaptors as well as the wye to provide 230VAC
    > from two 115 VAC outlets at dockside.

    Two 120 volt inlets do not necessarily quarantee that you will have 240 on
    board to operate a 240 volt appliance such as a washer/dryer: The two legs of
    240 are out of phase with each other and so must the two 120 volt inputs, which
    is not always the case.

    Best--Michael Oritt
    Durbeck 48--NAMASTE