| Home | Mailing Lists | Bookstore | Weather | Tide Predictions | Bowditch |

Re: TWL: Re: RE: Raw Water Flow Meter

From: (no name) (no email)
Date: Sat Nov 01 2003 - 18:18:17 EST

  • Next message: Dick Schroder: "RE: TWL: Fresh Water"

    In a message dated 11/1/2003 5:34:27 PM Eastern Standard Time,
     writes:

    > Wouldn't a thermotstat with alarm on the water cooled exhaust be simpler to
    > install and cheaper?
    >

    Not really very difficult to install a flow detector--just splice it into
    your intake line and run a circuit up to your alarm panel, etc. I use both that
    and a temperature-driven contactor for the simple reason that no flow is RIGHT
    NOW whereas temperature is a relative thing and might be due to reasons other
    than no raw water coolant.

    Best--Michael Oritt
    Durbeck 48--NAMASTE