Wouldn't a thermotstat with alarm on the water cooled exhaust be simpler to
install and cheaper?
Andina Foster,
> I have recently installed water flow detectors on the output side of my
> Main, AC genset and DC genset engine cooling systems. While they do not
> provide the 'more analog' type of information that you suggest, they do
> provide the 'more binary' FLOW / NOFLOW type of information that drives
> an alarm buzzer. While I think your idea has interest in an application
> where the instruments are being monitored (like main engine underway), I
> was more interested in the case where a genset intake sucks up a plastic
> bag or sea strainer clogs when I am not in front of the instruments. I
> have had both of these happen to me in the past.
>
> Jerry Finsen
> KK48 Whaleback "Capella"