RE: lv-ab: Fridge not working

From: ahmet erkan (no email)
Date: Tue Dec 28 2004 - 08:58:34 EST

  • Next message: Edwin F. Kelly: "lv-ab: Tsunami report"

    >Have A/B 200 that has begun cycling on abt 30 seconds & off 10 seconds.
    >Its not cooling, has abt 50 # of R134 . Can anyone help ?

    Hi Randy,

    I have seen this kind of periodic behavior in a automotive A/C unit when a
    pin hole in the condenser leaked the gas. If you are filling the system with
    a small bottle, immersing the bottle in a pot of boiling water helps
    transferring the contents into the system. If adding gas changes the 30
    second ON, 10 second OFF timing where the ON time is elongated, more gas may
    solve the problem. Motor windings have thermal protectors that interrupt the
    ON time if the compressor freezes but it is unlikely that the winding can
    cool down in 10 seconds to re-start. It is plausible that the pressure
    sensor in the intake is hitting the low limit.

    Good luck,